qpnp-fg-gen3: Handle false positives in battery missing detection
Battery missing detection interrupt fires prematurely for higher battery ID values than the desired range. Fix this by disabling BMD when battery is re-inserted and enable it after obtaining the battery ID. While at it, update the battery type shown in particular when a battery profile is not available. Change-Id: Ia5458a85289e47bda0a9f4bc59683af695974bc5 Signed-off-by: Subbaraman Narayanamurthy <subbaram@codeaurora.org>
This commit is contained in:
parent
3d493610e3
commit
1a53645674
1 changed files with 38 additions and 11 deletions
|
@ -799,7 +799,7 @@ static const char *fg_get_battery_type(struct fg_chip *chip)
|
|||
if (chip->bp.batt_type_str) {
|
||||
if (chip->profile_loaded)
|
||||
return chip->bp.batt_type_str;
|
||||
else
|
||||
else if (chip->profile_available)
|
||||
return LOADING_BATT_TYPE;
|
||||
}
|
||||
|
||||
|
@ -1617,6 +1617,18 @@ static int fg_esr_fcc_config(struct fg_chip *chip)
|
|||
return 0;
|
||||
}
|
||||
|
||||
static int fg_batt_missing_config(struct fg_chip *chip, bool enable)
|
||||
{
|
||||
int rc;
|
||||
|
||||
rc = fg_masked_write(chip, BATT_INFO_BATT_MISS_CFG(chip),
|
||||
BM_FROM_BATT_ID_BIT, enable ? BM_FROM_BATT_ID_BIT : 0);
|
||||
if (rc < 0)
|
||||
pr_err("Error in writing to %04x, rc=%d\n",
|
||||
BATT_INFO_BATT_MISS_CFG(chip), rc);
|
||||
return rc;
|
||||
}
|
||||
|
||||
static void fg_batt_avg_update(struct fg_chip *chip)
|
||||
{
|
||||
if (chip->charge_status == chip->prev_charge_status)
|
||||
|
@ -2833,7 +2845,6 @@ static irqreturn_t fg_batt_missing_irq_handler(int irq, void *data)
|
|||
u8 status;
|
||||
int rc;
|
||||
|
||||
fg_dbg(chip, FG_IRQ, "irq %d triggered\n", irq);
|
||||
rc = fg_read(chip, BATT_INFO_INT_RT_STS(chip), &status, 1);
|
||||
if (rc < 0) {
|
||||
pr_err("failed to read addr=0x%04x, rc=%d\n",
|
||||
|
@ -2841,23 +2852,39 @@ static irqreturn_t fg_batt_missing_irq_handler(int irq, void *data)
|
|||
return IRQ_HANDLED;
|
||||
}
|
||||
|
||||
fg_dbg(chip, FG_IRQ, "irq %d triggered sts:%d\n", irq, status);
|
||||
chip->battery_missing = (status & BT_MISS_BIT);
|
||||
|
||||
if (chip->battery_missing) {
|
||||
chip->profile_available = false;
|
||||
chip->profile_loaded = false;
|
||||
chip->soc_reporting_ready = false;
|
||||
} else {
|
||||
rc = fg_get_batt_profile(chip);
|
||||
if (rc < 0) {
|
||||
chip->soc_reporting_ready = true;
|
||||
pr_err("Error in getting battery profile, rc:%d\n", rc);
|
||||
return IRQ_HANDLED;
|
||||
}
|
||||
clear_battery_profile(chip);
|
||||
schedule_delayed_work(&chip->profile_load_work, 0);
|
||||
return IRQ_HANDLED;
|
||||
}
|
||||
|
||||
rc = fg_batt_missing_config(chip, false);
|
||||
if (rc < 0) {
|
||||
pr_err("Error in disabling BMD, rc=%d\n", rc);
|
||||
return IRQ_HANDLED;
|
||||
}
|
||||
|
||||
rc = fg_get_batt_profile(chip);
|
||||
if (rc < 0) {
|
||||
chip->soc_reporting_ready = true;
|
||||
pr_err("Error in getting battery profile, rc:%d\n", rc);
|
||||
goto enable_bmd;
|
||||
}
|
||||
|
||||
clear_battery_profile(chip);
|
||||
schedule_delayed_work(&chip->profile_load_work, 0);
|
||||
|
||||
enable_bmd:
|
||||
/* Wait for 200ms before enabling BMD again */
|
||||
msleep(200);
|
||||
rc = fg_batt_missing_config(chip, true);
|
||||
if (rc < 0)
|
||||
pr_err("Error in enabling BMD, rc=%d\n", rc);
|
||||
|
||||
return IRQ_HANDLED;
|
||||
}
|
||||
|
||||
|
|