[MMC] Don't check READY_FOR_DATA when reading
There's no point checking to see if the card is ready to accept data when we're reading from it - sending the command only wastes precious bus bandwidth. Signed-off-by: Russell King <rmk+kernel@arm.linux.org.uk>
This commit is contained in:
parent
42431acbac
commit
2ed6d22cec
1 changed files with 19 additions and 17 deletions
|
@ -231,6 +231,7 @@ static int mmc_blk_issue_rq(struct mmc_queue *mq, struct request *req)
|
|||
goto cmd_err;
|
||||
}
|
||||
|
||||
if (rq_data_dir(req) != READ) {
|
||||
do {
|
||||
int err;
|
||||
|
||||
|
@ -252,6 +253,7 @@ static int mmc_blk_issue_rq(struct mmc_queue *mq, struct request *req)
|
|||
if (mmc_decode_status(cmd.resp))
|
||||
goto cmd_err;
|
||||
#endif
|
||||
}
|
||||
|
||||
/*
|
||||
* A block was successfully transferred.
|
||||
|
|
Loading…