Introduce THERMAL_TREND_RAISE/DROP_FULL support for step_wise governor
step_wise governor should set the device cooling state to upper/lower limit directly when THERMAL_TREND_RAISE/DROP_FULL. Signed-off-by: Zhang Rui <rui.zhang@intel.com>
This commit is contained in:
parent
d069015e26
commit
3dbfff3dfe
1 changed files with 46 additions and 18 deletions
|
@ -35,21 +35,54 @@
|
||||||
* state for this trip point
|
* state for this trip point
|
||||||
* b. if the trend is THERMAL_TREND_DROPPING, use lower cooling
|
* b. if the trend is THERMAL_TREND_DROPPING, use lower cooling
|
||||||
* state for this trip point
|
* state for this trip point
|
||||||
|
* c. if the trend is THERMAL_TREND_RAISE_FULL, use upper limit
|
||||||
|
* for this trip point
|
||||||
|
* d. if the trend is THERMAL_TREND_DROP_FULL, use lower limit
|
||||||
|
* for this trip point
|
||||||
|
* If the temperature is lower than a trip point,
|
||||||
|
* a. if the trend is THERMAL_TREND_RAISING, do nothing
|
||||||
|
* b. if the trend is THERMAL_TREND_DROPPING, use lower cooling
|
||||||
|
* state for this trip point, if the cooling state already
|
||||||
|
* equals lower limit, deactivate the thermal instance
|
||||||
|
* c. if the trend is THERMAL_TREND_RAISE_FULL, do nothing
|
||||||
|
* d. if the trend is THERMAL_TREND_DROP_FULL, use lower limit,
|
||||||
|
* if the cooling state already equals lower limit,
|
||||||
|
* deactive the thermal instance
|
||||||
*/
|
*/
|
||||||
static unsigned long get_target_state(struct thermal_instance *instance,
|
static unsigned long get_target_state(struct thermal_instance *instance,
|
||||||
enum thermal_trend trend)
|
enum thermal_trend trend, bool throttle)
|
||||||
{
|
{
|
||||||
struct thermal_cooling_device *cdev = instance->cdev;
|
struct thermal_cooling_device *cdev = instance->cdev;
|
||||||
unsigned long cur_state;
|
unsigned long cur_state;
|
||||||
|
|
||||||
cdev->ops->get_cur_state(cdev, &cur_state);
|
cdev->ops->get_cur_state(cdev, &cur_state);
|
||||||
|
|
||||||
if (trend == THERMAL_TREND_RAISING) {
|
switch (trend) {
|
||||||
|
case THERMAL_TREND_RAISING:
|
||||||
|
if (throttle)
|
||||||
cur_state = cur_state < instance->upper ?
|
cur_state = cur_state < instance->upper ?
|
||||||
(cur_state + 1) : instance->upper;
|
(cur_state + 1) : instance->upper;
|
||||||
} else if (trend == THERMAL_TREND_DROPPING) {
|
break;
|
||||||
cur_state = cur_state > instance->lower ?
|
case THERMAL_TREND_RAISE_FULL:
|
||||||
(cur_state - 1) : instance->lower;
|
if (throttle)
|
||||||
|
cur_state = instance->upper;
|
||||||
|
break;
|
||||||
|
case THERMAL_TREND_DROPPING:
|
||||||
|
if (cur_state == instance->lower) {
|
||||||
|
if (!throttle)
|
||||||
|
cur_state = -1;
|
||||||
|
} else
|
||||||
|
cur_state -= 1;
|
||||||
|
break;
|
||||||
|
case THERMAL_TREND_DROP_FULL:
|
||||||
|
if (cur_state == instance->lower) {
|
||||||
|
if (!throttle)
|
||||||
|
cur_state = -1;
|
||||||
|
} else
|
||||||
|
cur_state = instance->lower;
|
||||||
|
break;
|
||||||
|
default:
|
||||||
|
break;
|
||||||
}
|
}
|
||||||
|
|
||||||
return cur_state;
|
return cur_state;
|
||||||
|
@ -76,7 +109,7 @@ static void update_instance_for_throttle(struct thermal_zone_device *tz,
|
||||||
if (instance->trip != trip)
|
if (instance->trip != trip)
|
||||||
continue;
|
continue;
|
||||||
|
|
||||||
instance->target = get_target_state(instance, trend);
|
instance->target = get_target_state(instance, trend, true);
|
||||||
|
|
||||||
/* Activate a passive thermal instance */
|
/* Activate a passive thermal instance */
|
||||||
if (instance->target == THERMAL_NO_TARGET)
|
if (instance->target == THERMAL_NO_TARGET)
|
||||||
|
@ -87,28 +120,23 @@ static void update_instance_for_throttle(struct thermal_zone_device *tz,
|
||||||
}
|
}
|
||||||
|
|
||||||
static void update_instance_for_dethrottle(struct thermal_zone_device *tz,
|
static void update_instance_for_dethrottle(struct thermal_zone_device *tz,
|
||||||
int trip, enum thermal_trip_type trip_type)
|
int trip, enum thermal_trip_type trip_type,
|
||||||
|
enum thermal_trend trend)
|
||||||
{
|
{
|
||||||
struct thermal_instance *instance;
|
struct thermal_instance *instance;
|
||||||
struct thermal_cooling_device *cdev;
|
|
||||||
unsigned long cur_state;
|
|
||||||
|
|
||||||
list_for_each_entry(instance, &tz->thermal_instances, tz_node) {
|
list_for_each_entry(instance, &tz->thermal_instances, tz_node) {
|
||||||
if (instance->trip != trip ||
|
if (instance->trip != trip ||
|
||||||
instance->target == THERMAL_NO_TARGET)
|
instance->target == THERMAL_NO_TARGET)
|
||||||
continue;
|
continue;
|
||||||
|
|
||||||
cdev = instance->cdev;
|
instance->target = get_target_state(instance, trend, false);
|
||||||
cdev->ops->get_cur_state(cdev, &cur_state);
|
|
||||||
|
|
||||||
instance->target = cur_state > instance->lower ?
|
|
||||||
(cur_state - 1) : THERMAL_NO_TARGET;
|
|
||||||
|
|
||||||
/* Deactivate a passive thermal instance */
|
/* Deactivate a passive thermal instance */
|
||||||
if (instance->target == THERMAL_NO_TARGET)
|
if (instance->target == THERMAL_NO_TARGET)
|
||||||
update_passive_instance(tz, trip_type, -1);
|
update_passive_instance(tz, trip_type, -1);
|
||||||
|
|
||||||
cdev->updated = false; /* cdev needs update */
|
instance->cdev->updated = false; /* cdev needs update */
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
@ -133,7 +161,7 @@ static void thermal_zone_trip_update(struct thermal_zone_device *tz, int trip)
|
||||||
if (tz->temperature >= trip_temp)
|
if (tz->temperature >= trip_temp)
|
||||||
update_instance_for_throttle(tz, trip, trip_type, trend);
|
update_instance_for_throttle(tz, trip, trip_type, trend);
|
||||||
else
|
else
|
||||||
update_instance_for_dethrottle(tz, trip, trip_type);
|
update_instance_for_dethrottle(tz, trip, trip_type, trend);
|
||||||
|
|
||||||
mutex_unlock(&tz->lock);
|
mutex_unlock(&tz->lock);
|
||||||
}
|
}
|
||||||
|
|
Loading…
Add table
Reference in a new issue