staging: comedi: s626: clarify the cmd->start_arg validation and use

This driver supports a cmd->start_src of TRIG_NOW, TRIG_INT or TRIG_EXT.

Clarify the cmd->start_arg validation in Step 3 of the (*do_cmdtest).

For a TRIG_INT source, the cmd->start_arg is actually the valid
trig_num that is used by the async (*inttrig) callback.

Refactor the (*inttrig) function so that the cmd->start_arg is used
to check the trig_num instead of the open coded value.

Signed-off-by: H Hartley Sweeten <hsweeten@visionengravers.com>
Reviewed-by: Ian Abbott <abbotti@mev.co.uk>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
H Hartley Sweeten 2014-04-17 10:08:07 -07:00 committed by Greg Kroah-Hartman
parent cb789b8014
commit 478da5c9ad

View file

@ -2076,9 +2076,12 @@ static int s626_ai_load_polllist(uint8_t *ppl, struct comedi_cmd *cmd)
}
static int s626_ai_inttrig(struct comedi_device *dev,
struct comedi_subdevice *s, unsigned int trignum)
struct comedi_subdevice *s,
unsigned int trig_num)
{
if (trignum != 0)
struct comedi_cmd *cmd = &s->async->cmd;
if (trig_num != cmd->start_arg)
return -EINVAL;
/* Start executing the RPS program */
@ -2314,12 +2317,18 @@ static int s626_ai_cmdtest(struct comedi_device *dev,
if (err)
return 2;
/* step 3: make sure arguments are trivially compatible */
/* Step 3: check if arguments are trivially valid */
if (cmd->start_src != TRIG_EXT)
switch (cmd->start_src) {
case TRIG_NOW:
case TRIG_INT:
err |= cfc_check_trigger_arg_is(&cmd->start_arg, 0);
if (cmd->start_src == TRIG_EXT)
break;
case TRIG_EXT:
err |= cfc_check_trigger_arg_max(&cmd->start_arg, 39);
break;
}
if (cmd->scan_begin_src == TRIG_EXT)
err |= cfc_check_trigger_arg_max(&cmd->scan_begin_arg, 39);
if (cmd->convert_src == TRIG_EXT)