ARM: dts: msm: reduce VDD_GFX CPR max floor to ceiling range for MSM8998v2
Reduce the VDD_GFX CPR maximum floor to ceiling voltage range for each corner in order to meet the most recent hardware guidelines. Change-Id: Ie70a698fbed442e8826f0bc30c5ef6bdfd5b3e1f CRs-Fixed: 1098577 Signed-off-by: David Collins <collinsd@codeaurora.org>
This commit is contained in:
parent
b3ce4f6026
commit
4bf6721985
1 changed files with 1 additions and 1 deletions
|
@ -989,7 +989,7 @@
|
||||||
0 29000 11000 0>;
|
0 29000 11000 0>;
|
||||||
|
|
||||||
qcom,cpr-floor-to-ceiling-max-range =
|
qcom,cpr-floor-to-ceiling-max-range =
|
||||||
<50000 50000 50000 50000 50000 50000 70000 70000>;
|
<40000 40000 40000 40000 40000 40000 50000 50000>;
|
||||||
|
|
||||||
qcom,cpr-fused-closed-loop-voltage-adjustment-map =
|
qcom,cpr-fused-closed-loop-voltage-adjustment-map =
|
||||||
<0 0 0 0 1 2 3 4>;
|
<0 0 0 0 1 2 3 4>;
|
||||||
|
|