ARM: shmobile: r8a7779: Remove GENPD_FLAG_PM_CLK flag

The R-Car SYSC PM Domain only manages power domains for the main CPUs
and for coprocessors. It does not fill in the genpd .{at,de}tach_dev()
callbacks, and no power management clocks are registered for devices.
Hence pm_clk_{suspend,resume}() are no-ops, and setting of the
GENPD_FLAG_PM_CLK flag can be removed.

Originally the clock handling was copied from the R-Mobile PM Domain
code, which does manage a clock domain, in addition to device power
domains.

Signed-off-by: Geert Uytterhoeven <geert+renesas@glider.be>
Signed-off-by: Simon Horman <horms+renesas@verge.net.au>
This commit is contained in:
Geert Uytterhoeven 2015-06-04 20:22:33 +02:00 committed by Simon Horman
parent 23e95fc296
commit 564ec12832

View file

@ -83,7 +83,6 @@ static void r8a7779_init_pm_domain(struct r8a7779_pm_domain *r8a7779_pd)
{
struct generic_pm_domain *genpd = &r8a7779_pd->genpd;
genpd->flags = GENPD_FLAG_PM_CLK;
pm_genpd_init(genpd, NULL, false);
genpd->dev_ops.active_wakeup = pd_active_wakeup;
genpd->power_off = pd_power_down;