ARM: dts: msm: increase VDD_APC LowSVS/SVS ceiling voltages for msmcobalt
In order to guarantee stable operation some parts may require elevated voltages when operating at LowSVS or SVS corners. Thus, increase the VDD_APC0 and VDD_APC1 CPR ceiling voltages for the LowSVS and SVS corners to match the Nominal ceiling voltage. Change-Id: I4e50943923aabae104c8d2c8f512b28693132bbb CRs-Fixed: 1008621 Signed-off-by: Osvaldo Banuelos <osvaldob@codeaurora.org>
This commit is contained in:
parent
ed13ce6df1
commit
a5cfe2aa2a
1 changed files with 6 additions and 6 deletions
|
@ -621,9 +621,9 @@
|
|||
qcom,cpr-corner-fmax-map = <7 10 17 22>;
|
||||
|
||||
qcom,cpr-voltage-ceiling =
|
||||
<696000 696000 696000 696000
|
||||
696000 696000 696000 768000
|
||||
768000 768000 896000 896000
|
||||
<896000 896000 896000 896000
|
||||
896000 896000 896000 896000
|
||||
896000 896000 896000 896000
|
||||
896000 896000 896000 896000
|
||||
896000 1032000 1032000 1032000
|
||||
1112000 1112000>;
|
||||
|
@ -707,9 +707,9 @@
|
|||
qcom,cpr-corner-fmax-map = <8 12 18 25>;
|
||||
|
||||
qcom,cpr-voltage-ceiling =
|
||||
<696000 696000 696000 696000
|
||||
696000 696000 696000 696000
|
||||
768000 768000 768000 768000
|
||||
<896000 896000 896000 896000
|
||||
896000 896000 896000 896000
|
||||
896000 896000 896000 896000
|
||||
896000 896000 896000 896000
|
||||
896000 896000 1032000 1032000
|
||||
1032000 1032000 1112000 1112000
|
||||
|
|
Loading…
Add table
Reference in a new issue