power: bcl: Add frequency mitigation as an optional property for BCL
For targets with LMH DCVSh hardware and OSM, BCL software frequency mitigation is not required. Since hardware is doing the frequency mitigation, there is no need for the HLOS BCL frequency mitigation. So make the properties "qcom,mitigation-freq-khz" and "qcom,thermal-handle" as optional properties. Change-Id: I0062f3b39f00ff2f0e74affcffbcf1afd89d3b2f Signed-off-by: Manaf Meethalavalappu Pallikunhi <manafm@codeaurora.org>
This commit is contained in:
parent
54fb4f8396
commit
c2ec16b9e1
2 changed files with 42 additions and 22 deletions
|
@ -38,17 +38,19 @@ Optional parameters:
|
|||
- qcom,bcl-framework-interface: If this property is defined, then the BCL uses
|
||||
the BCL framework for monitoring battery voltage and current.
|
||||
When this property is defined, the 'qcom,high-threshold-uamp',
|
||||
'qcom,low-threshold-uamp', 'qcom,mitigation-freq-khz',
|
||||
'qcom,vph-high-threshold-uv', 'qcom,vph-low-threshold-uv' and
|
||||
'qcom,thermal-handle' properties should be defined in the
|
||||
'qcom,ibat-monitor' node.
|
||||
'qcom,low-threshold-uamp', 'qcom,vph-high-threshold-uv',
|
||||
'qcom,vph-low-threshold-uv' and 'qcom,thermal-handle' properties
|
||||
should be defined in the 'qcom,ibat-monitor' node.
|
||||
- qcom,bcl-hotplug-list = <hotplug-phandle-list>: List of phandles to the cores
|
||||
that are to be hotplugged, when battery current limit condition
|
||||
is reached.
|
||||
- qcom,bcl-soc-hotplug-list: List of phandles to the cores that are to be hotplugged,
|
||||
when battery SOC limit condition is reached.
|
||||
- qcom,bcl-freq-control-list: List of phandles to the cores that are to be frequency
|
||||
mitigated when BCL condition is reached.
|
||||
- qcom,bcl-freq-control-list: This optional property takes list of phandles to the
|
||||
cores that are to be frequency mitigated when BCL condition is
|
||||
reached. When this property is defined, 'qcom,mitigation-freq-khz'
|
||||
and 'qcom,thermal-handle' should be defined in the
|
||||
'qcom,ibat-monitor' node.
|
||||
- qcom,bcl-no-bms: This is an optional node for BCL IAVAIL monitor mode.
|
||||
If this property is defined, BCL IAVAIL monitor gets rbat value
|
||||
from power supply battery module instead of bms module.
|
||||
|
@ -65,10 +67,12 @@ Optional nodes:
|
|||
which the BCL driver should cap the maximum frequency.
|
||||
* qcom,low-threshold-uamp: The battery current, in microampere, below
|
||||
which the BCL driver should clear the CPU frequency mitigation.
|
||||
* qcom,mitigation-freq-khz: The maximum frequency value the BCL driver
|
||||
should mitigate the CPUS's with. This frequency shouldn't be
|
||||
less than the minimum frequency request that the kernel thermal
|
||||
monitor driver places during vdd restriction.
|
||||
* qcom,mitigation-freq-khz: This optional property defines the maximum
|
||||
frequency value the BCL driver should mitigate the CPUS's with.
|
||||
This property is valid only if 'qcom,bcl-freq-control-list' is
|
||||
defined in bcl parent node. This frequency shouldn't be less than
|
||||
the minimum frequency request that the kernel thermal monitor
|
||||
driver places during vdd restriction.
|
||||
* qcom,ibat-channel: The ADC hardware's Ibat channel number.
|
||||
* qcom,uv-to-ua-numerator: The conversion parameter required for converting
|
||||
the voltage measure from ADC hardware to current value.
|
||||
|
@ -92,7 +96,8 @@ Optional nodes:
|
|||
used by BCL driver to get the minimum frequency request that the
|
||||
thermal driver places during vdd restriction. This frequency
|
||||
value will be the lowest max frequency value the BCL driver can
|
||||
request.
|
||||
request. This property is valid only if 'qcom,bcl-freq-control-list'
|
||||
is defined in bcl parent node.
|
||||
* qcom,soc-low-threshold: The battery SOC percentage threshold below which
|
||||
mitigation needs to be applied.
|
||||
|
||||
|
|
|
@ -1495,10 +1495,7 @@ static int probe_bcl_periph_prop(struct bcl_context *bcl)
|
|||
bcl->ibat_high_thresh.trip_value);
|
||||
if (ret)
|
||||
goto ibat_probe_exit;
|
||||
BCL_FETCH_DT_U32(ibat_node, key, "qcom,mitigation-freq-khz", ret,
|
||||
bcl->bcl_p_freq_max);
|
||||
if (ret)
|
||||
goto ibat_probe_exit;
|
||||
|
||||
BCL_FETCH_DT_U32(ibat_node, key, "qcom,vph-high-threshold-uv", ret,
|
||||
bcl->vbat_high_thresh.trip_value);
|
||||
if (ret)
|
||||
|
@ -1520,7 +1517,18 @@ static int probe_bcl_periph_prop(struct bcl_context *bcl)
|
|||
= bcl->ibat_low_thresh.trip_notify = bcl_periph_ibat_notify;
|
||||
bcl->ibat_high_thresh.trip_data
|
||||
= bcl->ibat_low_thresh.trip_data = (void *) bcl;
|
||||
get_vdd_rstr_freq(bcl, ibat_node);
|
||||
|
||||
if (bcl_frequency_mask) {
|
||||
BCL_FETCH_DT_U32(ibat_node, key, "qcom,mitigation-freq-khz",
|
||||
ret, bcl->bcl_p_freq_max);
|
||||
if (ret)
|
||||
goto ibat_probe_exit;
|
||||
get_vdd_rstr_freq(bcl, ibat_node);
|
||||
} else {
|
||||
bcl->bcl_p_freq_max = UINT_MAX;
|
||||
bcl->thermal_freq_limit = 0;
|
||||
}
|
||||
|
||||
bcl->bcl_p_freq_max = max(bcl->bcl_p_freq_max, bcl->thermal_freq_limit);
|
||||
|
||||
bcl->btm_mode = BCL_MONITOR_DISABLED;
|
||||
|
@ -1574,11 +1582,6 @@ static int probe_btm_properties(struct bcl_context *bcl)
|
|||
goto btm_probe_exit;
|
||||
bcl->btm_high_threshold_uv = current_to_voltage(bcl, curr_ua);
|
||||
|
||||
key = "qcom,mitigation-freq-khz";
|
||||
ret = of_property_read_u32(ibat_node, key, &bcl->btm_freq_max);
|
||||
if (ret < 0)
|
||||
goto btm_probe_exit;
|
||||
|
||||
key = "qcom,ibat-channel";
|
||||
ret = of_property_read_u32(ibat_node, key, &bcl->btm_ibat_chan);
|
||||
if (ret < 0)
|
||||
|
@ -1618,7 +1621,17 @@ static int probe_btm_properties(struct bcl_context *bcl)
|
|||
ret = PTR_ERR(bcl->btm_vadc_dev);
|
||||
goto btm_probe_exit;
|
||||
}
|
||||
get_vdd_rstr_freq(bcl, ibat_node);
|
||||
|
||||
if (bcl_frequency_mask) {
|
||||
key = "qcom,mitigation-freq-khz";
|
||||
ret = of_property_read_u32(ibat_node, key, &bcl->btm_freq_max);
|
||||
if (ret < 0)
|
||||
goto btm_probe_exit;
|
||||
get_vdd_rstr_freq(bcl, ibat_node);
|
||||
} else {
|
||||
bcl->btm_freq_max = UINT_MAX;
|
||||
bcl->thermal_freq_limit = 0;
|
||||
}
|
||||
bcl->btm_freq_max = max(bcl->btm_freq_max, bcl->thermal_freq_limit);
|
||||
|
||||
bcl->btm_mode = BCL_MONITOR_DISABLED;
|
||||
|
@ -1738,6 +1751,8 @@ static int bcl_probe(struct platform_device *pdev)
|
|||
}
|
||||
}
|
||||
for_each_possible_cpu(cpu) {
|
||||
if (!(bcl_frequency_mask & BIT(cpu)))
|
||||
continue;
|
||||
snprintf(cpu_str, MAX_CPU_NAME, "cpu%d", cpu);
|
||||
bcl->cpufreq_handle[cpu] = devmgr_register_mitigation_client(
|
||||
&pdev->dev, cpu_str, NULL);
|
||||
|
|
Loading…
Add table
Reference in a new issue