Merge "qpnp-fg-gen3: notify charger with float voltage and FCC"
This commit is contained in:
commit
d3ac4bf6d2
1 changed files with 33 additions and 0 deletions
|
@ -1644,6 +1644,37 @@ out:
|
|||
return rc;
|
||||
}
|
||||
|
||||
static void fg_notify_charger(struct fg_chip *chip)
|
||||
{
|
||||
union power_supply_propval prop = {0, };
|
||||
int rc;
|
||||
|
||||
if (!is_charger_available(chip)) {
|
||||
pr_warn("Charger not available yet?\n");
|
||||
return;
|
||||
}
|
||||
|
||||
prop.intval = chip->bp.float_volt_uv;
|
||||
rc = power_supply_set_property(chip->batt_psy,
|
||||
POWER_SUPPLY_PROP_VOLTAGE_MAX, &prop);
|
||||
if (rc < 0) {
|
||||
pr_err("Error in setting voltage_max property on batt_psy, rc=%d\n",
|
||||
rc);
|
||||
return;
|
||||
}
|
||||
|
||||
prop.intval = chip->bp.fastchg_curr_ma;
|
||||
rc = power_supply_set_property(chip->batt_psy,
|
||||
POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT_MAX, &prop);
|
||||
if (rc < 0) {
|
||||
pr_err("Error in setting constant_charge_current_max property on batt_psy, rc=%d\n",
|
||||
rc);
|
||||
return;
|
||||
}
|
||||
|
||||
fg_dbg(chip, FG_STATUS, "Notified charger on float voltage and FCC\n");
|
||||
}
|
||||
|
||||
static void profile_load_work(struct work_struct *work)
|
||||
{
|
||||
struct fg_chip *chip = container_of(work,
|
||||
|
@ -1709,6 +1740,7 @@ done:
|
|||
rc);
|
||||
}
|
||||
|
||||
fg_notify_charger(chip);
|
||||
chip->profile_loaded = true;
|
||||
fg_dbg(chip, FG_STATUS, "profile loaded successfully");
|
||||
out:
|
||||
|
@ -1798,6 +1830,7 @@ static int fg_psy_get_property(struct power_supply *psy,
|
|||
break;
|
||||
case POWER_SUPPLY_PROP_VOLTAGE_MAX_DESIGN:
|
||||
pval->intval = chip->bp.float_volt_uv;
|
||||
break;
|
||||
case POWER_SUPPLY_PROP_CYCLE_COUNT:
|
||||
pval->intval = fg_get_cycle_count(chip);
|
||||
break;
|
||||
|
|