staging: comedi: usbduxsigma: check for invalid 'ao_timer' in all cases
Make sure to check that the 'ao_timer' value is valid for both the high speed and low speed cases in usbduxsigma_ao_cmdtest(). Signed-off-by: H Hartley Sweeten <hsweeten@visionengravers.com> Cc: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
parent
b986be8527
commit
dd64d1efda
1 changed files with 2 additions and 2 deletions
|
@ -994,9 +994,9 @@ static int usbduxsigma_ao_cmdtest(struct comedi_device *dev,
|
|||
* we get all channels at once
|
||||
*/
|
||||
devpriv->ao_timer = cmd->scan_begin_arg / 1000000;
|
||||
if (devpriv->ao_timer < 1)
|
||||
err |= -EINVAL;
|
||||
}
|
||||
if (devpriv->ao_timer < 1)
|
||||
err |= -EINVAL;
|
||||
|
||||
if (cmd->stop_src == TRIG_COUNT) {
|
||||
/* not continuous, use counter */
|
||||
|
|