A small fraction of MSM8996v3 parts with CPR revision 0 to 5 may not operate properly at very low VDD_APCC voltages. Therefore increase the VDD_APCC CPR floor voltage for these parts to 625 mV in order to guarantee stable operation. Also change the maximum CPR floor to ceiling voltage range from 80 mV to 50 mV for all MinSVS and LowSVS corners in order to ensure stable operation. Change-Id: I71c32aac8ef7d54dfcf48098aaf5d5909762df15 CRs-Fixed: 981898 Signed-off-by: David Collins <collinsd@codeaurora.org> |
||
---|---|---|
.. | ||