DMIC clock on ECPP(Echo Cancellation Ping-Pong) hardware path
can run at lower clock rate to avoid power consumption. Select
ECPP dmic clock rate when decimator is connected only to ECPP
path.
CRs-fixed: 1022917
Change-Id: I968e1fe6b099ebf5334eadb209219181293b207f
Signed-off-by: Sudheer Papothi <spapothi@codeaurora.org>
Signed-off-by: Vidyakumar Athota <vathota@codeaurora.org>
DMIC clock on ECPP(Echo Cancellation Ping-Pong) path can be set to
lower clock rate to avoid power consumption. Change configures the
DMIC clock rate on ECPP path based on device tree settings.
CRs-fixed: 1022917
Change-Id: I03e1a7f5ef3cf1b1907c03a3d38965ce3a611bc4
Signed-off-by: Sudheer Papothi <spapothi@codeaurora.org>
Signed-off-by: Vidyakumar Athota <vathota@codeaurora.org>
WCD9335 codec has single master clock supply widget for both
playback and recording paths. Adding separate clock supply
for playback and recording paths will help handle low power
audio recording usecases without affecting playback usecases.
Change is to enable separate clock supply widgets for playback
and recording paths.
CRs-fixed: 1022917
Change-Id: I3978d2c53f2b04104d9d279f8acad60326f9405c
Signed-off-by: Sudheer Papothi <spapothi@codeaurora.org>
Signed-off-by: Vidyakumar Athota <vathota@codeaurora.org>
Initialize the return value before it is used in the driver to
make sure valid return value is returned.
CRs-Fixed: 1050136
Change-Id: I3e2c524ac87d57ae33cd0f28b9c62b2a39ee79ad
Signed-off-by: Runmin Wang <runminw@codeaurora.org>
The set_rate requests from the display port clocks should always
make their way upto the DP PLL. Add the NO_RATE_CACHE flag to
clocks in that path in order to let this happen.
CRs-Fixed: 1050007
Change-Id: I6a848b04756b92f9b1149705176e8f4088b2a945
Signed-off-by: Deepak Katragadda <dkatraga@codeaurora.org>
Ensure we don't try to call online/offline functions with a
null-pointer.
CRs-fixed: 1049957
Change-Id: I6fa8f9bde5d5fd0680b5c571ba3cc99bd1f508b1
Signed-off-by: Olav Haugan <ohaugan@codeaurora.org>
Re-enable QTAGUID so that bandwidth control is possible from
userspace now that stability issues have been resolved by
picking upstream commits.
Change-Id: If3b0be88f28da82a08dc4cc67006e8ee8ced5a72
CRs-Fixed: 1035969
Signed-off-by: Bryse Flowers <bflowers@codeaurora.org>
Register a notifier callback with the power_supply framework
to detect when the bms power_supply is available so that
it can be used to query the battery properties required from
the fuel gauge for the maximum current query algorithm.
CRs-Fixed: 1043718
Change-Id: Icd535025a2f888e188f89841f32ac5b822f9b20d
Signed-off-by: Devesh Jhunjhunwala <deveshj@codeaurora.org>